    本主题由 koei123 于 2015-6-2 9:02:56 移动
张伟
注册用户
等级:列兵
经验:110
发帖:81
精华:0
注册:2011-12-22
状态:离线
发送短消息息给张伟 加好友    发送短消息息给张伟 发消息
发表于: IP:您无权察看 2015-3-20 8:56:37 | [全部帖] [楼主帖] 楼主

Error: [-15.570.0] A valid license could not be obtained by the network license manager
Issue:
You open an Autodesk product on the computer that contains the network license server and select Specify the License Server System in the FLEXnet License Finder dialog box, but the following error message is displayed:
"Network Licensing: Error [-15.570.0] A valid license could not be obtained by the network license manager"
Causes:

  • You are missing the license for the product you are attempting to open.
  • Your Autodesk Network License Manager (NLM) is installed on a Windows Server 2008 or Windows Vista/7 machine.
  • Your NLM and Autodesk product exist on the same workstation with IPv6 enabled.
  • Your Client system has an incorrect Date/Time (the server will reject license checkouts from clients that have a notable difference in date/time from the server).
  • Blocked port on license manager system.
  • You are running an IPV6 version when you should be running iPv4

Solution:
Verify and/or retrieve the proper license and make sure it is running in LMTOOLS.
If your NLM and your Autodesk product are installed on the same workstation, verify that the connection made to the NLM is not via IPv6.  If it is, disable IPv6 or redirect the protocol to use IPv4 instead.
Method #1:
To verify connectivity with your NLM server:

  1. Open a command prompt (Start > Run > CMD) and PING your server hostname:



北京联动北方科技有限公司

A typical IPv6 response for localhost loopback when the NLM is on the same machine may be one of the following:

  • ::1 
  • a full IPv6 address such as 3ffe:1900:4545:3:200:f8ff:fe21:67cf

Your results may look different.
If the response is an IPv6 as in the example above, you need to disable IPv6 on your Network LAN settings and verify PING again to ensure it has an IPv4 address in the format of xxx.xxx.xxx.xxx.
For more configuration changes, continue on to Method #2.
Method #2
If you are unable to disable IPv6 or need IPv6 on your network, change your system HOSTS file to redirect the protocol to use an IPv4 address instead.

  1. Verify that connectivity to the NLM server is using IPv6, as described in Method #1.  

If your response is an IPv6, you need to edit your HOSTS file to point the server hostname to an IPv4 address instead.  You need Administrative rights for this process.
—First ensure that the User Account Control (UAC) in Windows is disabled.  Open the Control Panel and choose System and Security:


北京联动北方科技有限公司

—Then choose Change User Account Control settings:


北京联动北方科技有限公司

—Finally, disable the UAC option by setting it to Never notify:


北京联动北方科技有限公司

Now you should be able to open and edit the Windows HOSTS file to make the necessary changes.
Find the file in the following location:
C:\Windows\system32\drivers\etc
Open the hosts file with Notepad.  You should have Administrator privileges when performing this task.
If the file is Read-only, you may need to make the file writable from within the file properties dialog box.
Your HOSTS file should appear similar to the image below.
If your NLM and Autodesk product are on the same machine:

  1. Comment out the IPv6 localhost address of ::1 by adding a # sign. 
  2. Add your hostname behind the IPv4 localhost 127.0.0.1 address as shown. 
  3. Save the file and close Notepad. 


北京联动北方科技有限公司

If your NLM is on a different server than your client installed software:

  1. Create a new entry for your NLM server with the correct IPv4 xxx.xxx.xxx.xxx formatted address followed by your server hostname and save the file then close Notepad. 
  2. Verify IPv4 connectivity by opening the Command prompt and PING the server hostname.  It should now read the appropriate IPv4 response.  If your NLM is local, it should read 127.0.0.1.  If the NLM is on a server, it should read the IP address of your server. 



北京联动北方科技有限公司

When you launch your Autodesk product, it should launch and obtain a license as appropriate.
Open ports 2080,27000-27009 on the server firewall for TCP incoming.
It is possible that a port is blocked on the machine housing the License Server. In this case we can force the CLIENT machine to use a different port.

  1. Right-click the My Computer icon.
  2. Click the Advanced tab.
  3. Click "Environment Variables".
  4. Under the System Variables window, click "New".
  5. In the Variable name field enter ADSKFLEX_LICENSE_FILE
  6. In the Variable value field enter 27000@YOUR_SERVER_NAME _OR _IP
  7. Click "Okay" and test

Uninstall the IPV6 manager and install the IPV4 version
http://knowledge.autodesk.com/support/autocad/troubleshooting/caas/downloads/content/autodesk-ipv4-network-license-manager-for-windows.html


--转自 北京联动北方科技有限公司